NZFDRP
DESCRIPTION OF FUNCTION, SECTION
28
They comprise a
• housing (1)
• guide nut (2)
• throttling screw (3)
• metering bush (4) and a
• spring (5).
Two symmetrically arranged throttle/check valves limit
flow by means of adjustable throttling spools in one
direction and give free return flow in the other. At
metering-out the fluid in line A2 reaches the line A1 via
the throttle position (6), a combination from the
metering bush (4) and the throttling screw (3). To set the
throttle orifice, use a 4 A/F hexagon key in the end (7) of
the self-locking throttling screw (3).
The 13 A/F locknut (8) provides additional security. Oil
flowing from the line A1 pushes the metering bush (4)
against the spring (5) and allows oil to flow freely from
line A1 to A2, operating as a check valve. By rotating the
valve about its long axis it can be mounted with either
of this two interface surfaces uppermost – one position
gives a METER-IN function, the other METER-OUT.
Valves type N-ZFDRP10 are double throttle/check valves
in sandwich plate design. They serve to limit a main or
pilot flow of one or two user ports.
MODULAR VALVES
THROTTLE CHECK
VALVES